Commercial cooling efficiency interview: the gap between rated and actual
India is installing air conditioners faster than it is making them perform. In this commercial cooling efficiency interview, Softdel’s Sachin Deshmukh argues that buying efficient equipment is no longer the hard part — the harder question is whether a building’s systems deliver their rated efficiency once installed, and what operations have to do with the answer.
Softdel, part of the Unidel Group
Softdel, part of the Unidel Group, was founded in 1999 and is headquartered in Stamford, Connecticut. It works on connecting devices, enterprises and people, with more than two decades of product engineering for the automation and controls industry, and a focus on smart buildings and smart factories. Its offering combines a product suite — communication stacks, simulation tools and IoT gateways — with services across device engineering, middleware, edge computing and cloud applications, and its intelligent building management platform is EdificeDX.
Its relevance to this commercial cooling efficiency interview is that the company sits at the seam the thesis describes: equipment that has a rated performance, a building that has an actual one, and the instrumentation in between that determines whether anyone knows the difference.
Sachin Deshmukh
Sachin Deshmukh is the CEO and Managing Director of Softdel, part of the Unidel Group, a role he has held since 2021. He brings more than 25 years across building automation, HVAC technology and connected infrastructure, and previously held leadership roles at Cybage Software and Zensar Technologies. He is an electronics engineering graduate from V.J.T.I., Mumbai, with an MBA from S. P. Jain Institute of Management and Research, and serves on the NASSCOM Regional Council and ER&D Chapter.
His argument in this commercial cooling efficiency interview is that the hard problem in cooling has moved. Buying an efficient air conditioner is no longer difficult — the market supplies them and the standards define them. What remains difficult is whether the systems inside a commercial building deliver their rated efficiency once installed, because HVAC performance, operating conditions, maintenance and building automation all shape real consumption.
That reframes efficiency as an operations problem rather than a procurement one. Readers will come away with a clearer view of what the rated-versus-actual gap actually is, how it gets measured in buildings that were not instrumented for it, which causes are cheapest to fix, and where connected controls and predictive maintenance genuinely help.
The gap
Q1. What is the rated-versus-actual efficiency gap?
SD: Rated efficiency is what equipment is designed to achieve under specified test conditions, while actual efficiency is how it performs in a real building, where operating conditions, maintenance practices and occupant requirements are constantly changing.
Let me take the example of HVAC systems. Equipment may have a high efficiency rating but still consume more energy than expected because of incorrect sequencing, simultaneous heating and cooling, poor scheduling or inefficient part-load operation.
This is where building automation and system integration become important. At Softdel, we focus on bringing equipment and operational data together to help address these system-level inefficiencies.
A Commercial Building
Q2. How large is it typically in a commercial building, and what is the single biggest contributor?
SD: I don’t think there is one universal percentage that can define the efficiency gap across commercial buildings. It depends on several factors, including the building’s age, climate, occupancy, commissioning quality and how effectively the building is operated and maintained. The gap can be significant, particularly in older buildings where equipment has evolved over time, but the controls and operating strategies have not kept pace.
If I had to identify one major contributor, it would be the absence of continuous, coordinated optimisation across building systems.
Take HVAC, for example. It is a major energy consumer in commercial buildings. Inefficient schedules, simultaneous heating and cooling, inappropriate temperature setpoints or equipment operating beyond occupancy hours can all result in avoidable energy consumption. This is an area where our customers have been leveraging Softdel’s EdificeDX platform to connect equipment data, improve visibility and move towards actionable insights on energy consumption and asset performance.
Measurement vs Actual Performance
Q3. To know actual performance you need data from the equipment. What does that require in a building that is fifteen years old and was never instrumented for it?
SD: I think the first thing to understand is that a 15-year-old building does not necessarily need a complete technology overhaul to become intelligent. A more practical approach is to assess the existing infrastructure, understand what data is already available and identify where additional instrumentation can deliver measurable value.
We would typically begin by examining the building’s assets, including chillers, air handling units, pumps, cooling towers, energy meters and existing controllers. The next step is to understand their connectivity capabilities and whether they support protocols such as BACnet, Modbus, LonWorks or proprietary communication standards.
Where possible, existing building management systems, gateways and protocol integration can be used to acquire operational data. Additional sensors may be introduced selectively to capture information that is not available, such as temperature, pressure, humidity, flow, occupancy or energy consumption.
Once that information is available, it needs to be contextualised against individual assets, zones and operating conditions. We can then establish performance baselines, identify anomalies and recommend corrective actions.
We have worked with customers on legacy asset modernisation, and Softdel’s experience in BACnet, Niagara, protocol integration and connected building platforms is particularly relevant here.
The larger point is that perfectly functional legacy equipment should not have to be replaced simply to make a building AI-ready. Often, connecting existing assets and making their data usable is a more economical and practical approach. The objective is not necessarily to install more sensors, but to generate reliable, contextualised data that can support better decisions.
Hardest Measurement Problem
Q4. What is the hardest measurement problem — sensor coverage, protocol access, or agreeing what the baseline should be?
SD: I would say the biggest challenge is not necessarily sensor availability. It is getting reliable, contextualised data from equipment that operates across different technology ecosystems and communication protocols.
In older buildings, you may have multiple generations of equipment, proprietary protocols and building management systems from different vendors. Even when equipment supports the same open communication standard, differences in implementation and configuration can create interoperability challenges.
So, from a technical standpoint, protocol access and interoperability are often the first hurdles.
However, when we move from collecting data to demonstrating actual energy savings, defining the right baseline becomes equally important. Without a credible baseline, it becomes difficult to establish whether an improvement has genuinely delivered measurable savings
Causes The Gap
Q5. What actually causes the gap: commissioning, maintenance, controls sequencing, setpoints, or occupant behaviour? Rank them.
SD: The efficiency gap is rarely the result of one isolated issue. In most buildings, several factors interact and contribute to the difference between rated and actual performance.
However, from a building automation and operational perspective, I would prioritise them in the following order:
– Controls sequencing
– Commissioning
– Maintenance
– Setpoints
– Occupant behaviour
Poor controls sequencing can result in equipment operating without proper coordination. Inadequate commissioning may mean systems are not functioning as originally designed, while maintenance issues can gradually reduce equipment efficiency.
Incorrect temperature setpoints and occupant-driven manual overrides can further contribute to unnecessary energy consumption.
I would emphasise that this is an operational prioritisation rather than a universal industry ranking. The relative importance of each factor will vary depending on the building and its operating conditions.
Cheapest to Fix
Q6. Which cause is cheapest to fix, and which gets ignored because it is unglamorous?
SD: Some of the most economical improvements are operational rather than technological.
Correcting equipment schedules, eliminating unnecessary operating hours, adjusting temperature setpoints and removing inappropriate manual overrides can often address avoidable energy consumption without requiring major infrastructure investments.
What tends to receive less attention is ongoing commissioning and routine controls maintenance.
These activities may not be as visible or exciting as installing a new building management system or deploying an AI platform, but they can make a significant difference to actual building performance.
Our approach at Softdel is to help customers make these operational inefficiencies visible through connected building intelligence, so they have the information needed to identify and correct them.
Controls and AI
Q7. Do connected controls close the gap, or mostly reveal it — and how would a client tell the difference?
SD: Connected controls initially help reveal the efficiency gap. Whether they actually close that gap depends on what happens next.
Simply connecting equipment and creating dashboards does not automatically translate into energy savings.
I look at this as a progression from visibility to intelligence and then optimisation.
For example, consider a building where the building management system identifies that chillers and pumps are operating longer than required.
The first step is visibility, where the system identifies the issue. Analytics then help determine why it is happening. Based on those insights, optimisation can recommend changes to equipment schedules, sequencing or operating parameters.
Finally, corrective action, whether automated or undertaken by building operators, needs to deliver measurable improvement.
That is how a customer can distinguish between a connected system that merely reports inefficiencies and one that actually helps address them.
Softdel’s EdificeDX platform is aligned with this progression, moving from equipment connectivity and monitoring towards energy optimisation and operational intelligence.
Genuinely Pay for Itself
Q8. Predictive maintenance: where does it genuinely pay for itself, and where is it a subscription with a dashboard?
SD: Predictive maintenance delivers the greatest value when it is applied to critical assets where unexpected failures can have significant operational or financial consequences.
In commercial buildings, this includes equipment such as chillers, pumps, compressors and cooling towers, where an unexpected breakdown can disrupt operations or affect energy performance.
But there is an important distinction between generating alerts and delivering actionable intelligence.
If a platform simply produces alerts without meaningful diagnostics, prioritisation or recommendations, its value can remain limited to monitoring.
Let me share two examples from our broader engineering portfolio.
In an engagement with a North American industrial HVAC OEM, AI-enabled predictive maintenance delivered approximately 30% lower maintenance costs and a 15% improvement in technician productivity.
In a separate intelligent battery energy storage system (BESS) engagement covering more than 50 sites, the reported outcomes included up to a twofold reduction in annual energy costs and approximately 20% lower equipment run hours.
These examples demonstrate the importance of connecting technology to measurable operational outcomes. Predictive maintenance needs to help customers make better maintenance decisions, rather than simply provide another dashboard.
Comfort Without Compromising
Q9. Cutting cooling without compromising comfort — where is the real trade-off, and who decides it?
SD: I don’t think the objective should be to reduce cooling at the expense of occupant comfort.
The real objective is to deliver the required level of comfort while consuming the least possible energy.
The trade-off is between maintaining comfort consistently and operating equipment more intelligently in response to changing occupancy, weather conditions, thermal loads and actual building requirements.
Building owners and facility managers need to define the comfort requirements and operating boundaries.
Building automation systems can then help optimise equipment performance within those parameters.
So, the idea is not to compromise comfort, but to avoid consuming more energy than is necessary to maintain it.
Putting to the test
Q10. The IEA figures put 130 to 150 million air conditioners into India between 2025 and 2030, with roughly 7 GW of peak demand per 1°C. What do those numbers imply for building operations specifically, as opposed to equipment standards?
SD: I think the larger implication is that India’s cooling challenge cannot be addressed through more efficient air conditioners alone.
We need efficient equipment, but we also need buildings that operate that equipment intelligently.
Equipment standards determine how efficiently an air conditioner is designed to operate. Building operations determine how, when and how much that equipment is actually used.
This distinction is important because even highly efficient equipment can consume more energy than necessary if it is operated with inefficient schedules, inappropriate temperature setpoints or poorly coordinated controls.
From a building operations perspective, the focus therefore needs to extend beyond equipment ratings to how cooling systems are managed and optimised during actual use.
Class of Building
Q11. What would prove you wrong — is there a class of building where the gap cannot be closed at reasonable cost?
SD: Absolutely. I would not suggest that every building can achieve high efficiency through connected controls and instrumentation alone.
There are situations where the underlying infrastructure is simply too inefficient, outdated or poorly designed for extensive retrofitting to make economic sense.
For example, a building with severely degraded HVAC systems, inadequate insulation, a poor building envelope or obsolete equipment may require fundamental infrastructure improvements before digital optimisation can deliver meaningful results.
I think it is useful to look at three broad categories.
In modern buildings, where building management systems and connected equipment are already available, optimisation can be relatively straightforward.
In brownfield buildings, legacy equipment can often be integrated through gateways, protocol converters and targeted instrumentation. This is where Softdel’s experience in BACnet, Niagara and legacy protocol integration becomes particularly relevant.
However, in severely outdated buildings, equipment replacement, electrical upgrades or improvements to the building envelope may be necessary before connected controls can make a meaningful difference.
Ultimately, the decision should be based on the economics of optimisation versus replacement. We should not assume that technology alone can solve every building performance problem.
Strongest Argument
Q12. What is the strongest argument against the controls-first thesis — that the real fix is better equipment and stricter enforcement of standards, not more instrumentation?
SD: I think the strongest argument is that intelligent controls cannot indefinitely compensate for fundamentally inefficient equipment or poor building design.
If the equipment itself is inefficient, replacing it with higher-performing alternatives and enforcing minimum efficiency standards becomes essential.
But I don’t see this as an either-or proposition.
Better equipment establishes the potential for higher efficiency. Intelligent controls and building operations help ensure that this potential is realised consistently under actual operating conditions.
So, in my view, both are necessary. Equipment efficiency and operational efficiency need to work together if we want to address the gap between rated and actual building performance.

TechRecast Analysis (The Recast)
The Shift in Context — Cooling efficiency has been treated as a specification problem: set a standard, label the equipment, let procurement do the rest. The claim here is that the specification is now the easy half, and that performance is decided after installation — in commissioning, in maintenance, in how a building automation system sequences equipment on a hot afternoon. That is where this commercial cooling efficiency interview sits.
Why This Interview Matters — The stakes are unusually concrete. India is adding cooling capacity at a pace that puts real load on the grid, and the gap between rated and actual performance is the difference between a demand forecast that holds and one that does not. A building that runs ten per cent worse than its equipment rating is not a rounding error at national scale.
Technology Perspective — The technical crux is that the rated figure is a laboratory condition, and the building is not a laboratory. Real performance depends on part-load behaviour, refrigerant charge, airflow, fouling, sensor calibration and control sequencing — none of which appear on a label. Measuring it requires instrumentation the building may not have, and interpreting it requires a baseline that someone has to agree to, which is a data and semantics problem before it is an AI problem.
Business and Market Perspective — The commercial logic is that the gap is where operating cost lives. A facility paying for energy it is not getting value from has a measurable loss, and the interventions that close it — retro-commissioning, control tuning, maintenance discipline — compete for capital against equipment replacement, which is easier to justify and easier to photograph.
Leadership Perspective
An electronics engineer running a building-automation firm is well placed to talk about the gap, but also sells the instrumentation that reveals it. The relevant lens is whether he distinguishes honestly between what the technology closes and what only operations discipline can close.
The Counterpoint — A fair sceptic would argue that the rated-versus-actual gap has been documented for decades under the name “performance gap” and is not new; that instrumentation often measures the problem without fixing it; that predictive maintenance rarely pays back at the scale vendors claim; and that stricter enforcement of commissioning standards would do more than another platform. On this view, the diagnosis is sound and the remedy is oversold. This is the strongest opposing case and deserves a direct answer.
What Comes Next — Watch three signals: whether performance-gap disclosure becomes part of building certification, whether predictive maintenance publishes measured payback periods, and whether grid-interactive building standards start regulating operational performance rather than installed equipment.
Industry Outlook
If Deshmukh is right, cooling efficiency shifts from a procurement decision to an operations discipline, and the value moves to firms that can measure and maintain building performance. If he is wrong, equipment standards and enforcement close the gap and instrumentation remains a reporting cost.
Key Takeaways
1. Buying efficient cooling equipment is no longer the hard part; delivering its rated efficiency in a real building is.
2. The gap between rated and actual performance is created by commissioning, maintenance, control sequencing and operating conditions.
3. Measuring actual performance requires instrumentation many buildings do not have, and a baseline somebody has to agree on.
4. Connected controls may reveal the gap more reliably than they close it — a distinction worth making explicit.
5. The comfort trade-off is real, and who gets to decide it is a governance question, not an engineering one.
6. The strongest counter-argument is that this “performance gap” has been documented for decades, and instrumentation often measures the problem rather than fixing it.